Anti-Ice and Rain - EICAS Messages

MessageLevelLightCondition
C ADIRU PITOT Advisory C ADIRU PITOT Centre ADIRU Probe Heat is inoperative.
L/R
AOA PROBE
Advisory L AOA
R AOA
AOA probe heat is inoperative.
CAPT PITOT Advisory CAPT PITOT Captain's Pitot Probe Heat is inoperative.
F/O PITOT Advisory FO PITOT First Officer's Pitot Probe Heat is inoperative.
STBY INST PITOT Advisory STBY INST PITOT Standby Instrument Pitot Probe Heat is inoperative.
L/R TAT PROBE
TAT PROBE
Advisory L TAT
R TAT
TAT Probe Heat is inoperative.
PROBE HEAT Advisory Two or more PITOT, AOA or TAT Two or more Probe Heats are inoperative.
MessageLevelLightCondition
L/R
ENG ANTI-ICE
Advisory VALVE Engine Anti-Ice valve [position] disagrees with switch position.
L/R
WING ANTI-ICE
Advisory VALVE Wing Anti-Ice valve [position] disagrees with switch position.
MessageLevelLightCondition
L/R
FWD WINDOW
Advisory INOP Window is not being heated.
L/R
SIDE WINDOW
Advisory INOP Window is not being heated.
WINDOW HEAT Advisory Two or more INOP Two or more Windows are not being heated.
MessageLevelLightCondition
ICE DET OFF Advisory   Ice Detecting sensor no longer detects ice.
ICE DET ON Advisory ICING Ice Detecting sensor detects ice.

Automatic Flight Next